In all electronic flash measurements, an analyzing feature simultaneously evaluates both flash and ambient light and displays the values in three ways: a combined readings of flash and ambient, b percentage of flash in the total exposure or c simultaneous display of flash, ambient and combined readings on the analog scale. Selecting settings is quick and easy with the built-in Jog wheel and cine shutter speeds up to frames per second makes the L a versatile tool in the most demanding lighting scenario.
Optional spot finders extend the versatility of the meter with a choice of 1, 5 or 10 degree measuring angles with a viewable parallax-free viewfinder. Skip to main content. Key Features All-weather digital ambient and flash light meter A simultaneous reading of flash and ambient light is analyzed. Simultaneous display of flash, ambient and combined readings on the analog display Retractable, Removable and Rotating Lumisphere Optional radio transmitter connects with PocketWizard flash slaves 9 memory banks are available in both Aperture Priority and Shutter Priority Modes, making contrast evaluation and averaging possible in both modes.
Dual ISO settings possible. Catalog Numbers International Catalog. International Catalog Info. Metering Type Sensor. Measuring System. Incident: retractable lumisphere, Reflected: with included reflected Lumigrid light attachment or NPFinder 1, 5, or 10 deg. Measuring Modes Flash. Measuring Range Flash Incident Light. Measuring Range Flash Reflected Light. ISO Range. Aperture Range Ambient Light. Aperture Range Flash Light. Shutter Speeds Range Ambient Light. Shutter Speeds Range Flash Light.
Frame Rate Range Ambient Light. EV Range Ambient Light. Radio System. Flash vs Ambient Analyzing. Exposure Compensation. Calibration Compensation. Table Of Contents. Quick Links. Table of Contents. Previous Page. Next Page. Measuring Instruments Sekonic L Operating Manual Sekonic operating manual digital camera ldr, ld, l 68 pages.
Sekonic digital camera operating manual ldr ld l 68 pages. The Flash Master L has undergone extensive quality controls at every step of manufacture.
Please read this instruction manual thoroughly, to be able to take advantage of its many features and to obtain the long service life it is designed for. Page 4: Parts Designation 1. Parts Designation q Lumisphere retracting ring! Actual display will never show as above. When using the Mini Light Receptor or a Booster optional accessories the LCD will be illuminated after measuring, regardless of the ambient light level.
Page 6 2. Before Using Attach the strap Attach the Strap 1 by passing the small end loop through the eyelet o and passing the other end of strap through it. Before Using Replacing battery during measurement or when using the memory function Always turn the power OFF before replacing batteries. If batteries are removed with the power ON, measurements and settings in memory can no longer be recalled. If after replacing the battery, or during measurements, strange screens displays that have not been set appear in the LCD, or nothing happens, no matter what button is pushed, remove the battery and wait at least ten seconds and then replace the battery.
Hold down the Mode set button! The last measurement is held until the lock is released, even if the Jog wheel t is accidentally moved. Page Basic Operation 4. Basic Operation Setting measuring mode Hold down the Mode set button!
Select the mode you want prior to beginning measurements. Basic Operation When set for incident light Incident light measurements can be performed with the lumisphere fully extended or in the retracted position.
You can switch between Lumisphere in the up position or retracted position by firmly rotating the Lumisphere retracting ring q until it clicks. Lumisphere Retracted Lumisphere When the Lumisphere is raised It is useful for distant objects such as landscapes, when you cannot go to the position of the subject, or for metering subjects that generate light neon signs, etc. Page Measurment 5.
Measurement Measuring ambient light In this measurement mode, we have the choice of shutter priority mode, aperture priority mode and EV mode.
Page Aperture Priority Mode 5. Measurement Aperture Priority mode 1. Turn the Jog wheel to set the desired f stop value. MODE Measured value shutter speed 3. Page Ev Mode 5. Measurement EV mode Open the Battery compartment cover! Page Cinematography 5. Measurement Cinematography 1. Turn the Jog wheel t to select the Cine Speed for the camera that will be used.
Page Measuring Flash Light 5. Measurement Measuring flash light This method of measurement can be done in the following modes; with cord, without cord, multiple flash with cord, multiple flash without cord and Wireless flash radio triggering mode with optional radio transmitter module. When Measuring flash light, the shutter speed and F stop value value combining ambient light and flash light: total amount of light are displayed. The ambient light and flash light are each displayed as separate values together with the total amount of light on the analog scale.
Page 20 5. Measurement 3. When the Measuring button! The ready to measure mode will continue for approximately 90 seconds. During this time, fire the flash and make a measurement. Measurement Cord multiple flash cumulative mode These measurements are used when the light generated by the flash is inadequate for proper exposure.
The repeated flash pops can be accumulated until the desired aperture is displayed. The cumulative number is infinite. Only one digit is displayed if the cumulative number is ten or more.
Under such conditions, it is recommended that you use the meter in the Cordless flash mode or wireless flash radio triggering mode, and keep the Synchro terminal cap in place. Page 23 5.
0コメント